  Datasheet File OCR Text:
  euro cassetes powering progress ? www.powerbox.com.au doc. no. pbc9 rev.c 28-4-11 C4800 series 2 4 0 0 - 5 0 0 0 a c / d c - d c / d c - b a t t e r y c h a r g e r s s i n g l e o u t p u t features ? dc input 10 - 800 v ? ac input 1 or 3-phase, 47 - 400 hz ? dc output 12-400v ? continuous short circuit protection ? overvoltage protection with auto restart ? thermal shutdown with auto restart ? industrial grade components ? compact and robust design dc/dc converters ac/dc power supplies 2400 w 3500 w 5000 w input vdc output vdc 10 ?16 vdc output amps 20?32 vdc output amps 40?64 vdc 50 ? 80 vdc output amps 80 ?160 vdc 160 ? 320 vdc 320?380 vdc 320?640 vdc 450?800 vdc output amps adj. range c 4802 136 c 4822 190 c 4832 c 4842 240 c 4852 c 4872 c 4882 z c 4872 g c 4872 k 260 12 11 ? 13 c 4803 116 c 4823 160 c 4833 c 4843 200 c 4853 c 4873 c 4883 z c 4873 g c 4873 k 220 15 14 ? 16 c 4804 92 c 4824 120 c 4834 c 4844 150 c 4854 c 4874 c 4884 z c 4874 g c 4874 k 160 24 23 ? 26 c 4805 80 c 4825 100 c 4835 c 4845 130 c 4855 c 4875 c 4885 z c 4875 g c 4875 k 140 28 26 ? 30 c 4809 44 c 4829 60 c 4839 c 4849 76 c 4859 c 4879 c 4889 z c 4879 g c 4879 k 80 48 45 ? 55 c 4806 36 c 4826 50 c 4836 c 4846 62 c 4856 c 4876 c 4886 z c 4876 g c 4876 k 66 60 58 ? 68 c 4807 20 c 4827 26 c 4837 c 4847 36 c 4857 c 4877 c 4887 z c 4877 g c 4877 k 40 110 100 ? 130 c 4807 j 12 c 4827 j 14 c 4837 j c 4847 j 20 c 4857 j c 4877 j c 4887 zj c 4877 gj c 4877 kj 20 200 190 ? 200 c 4808 10 c 4828 14 c 4838 c 4848 20 c 4858 c 4878 c 4888 z c 4878 g c 4878 k 20 220 200 ? 250 c 4808 j 6 c 4828 j 7 c 4838 j c 4848 j 10 c 4858 j c 4878 j c 4888 zj c 4878 gj c 4878 kj 10 400 380 ? 400 4 kw 5 kw input vac, 1-phase input vac, 3-phase output amps output vdc 115 20% output amps 230 + 15% ? 20% 3x200 + 15% ? 20% 3x400 + 15% ? 20% 3x480 + 15% ? 20% adj. range c 4862 260 3) c 4882 c 4862 v c 4882 v c 4892 v 260 12 11 ? 13 c 4864 220 3) c 4883 c 4863 v c 4883 v c 4893 v 220 15 14 ? 16 c 4865 150 c 4884 c 4864 v c 4884 v c 4894 v 160 24 23 ? 26 c 4869 130 c 4885 c 4865 v c 4885 v c 4895 v 140 28 26 ? 30 c 4866 72 c 4889 c 4869 v c 4889 v c 4899 v 80 48 45 ? 55 c 4867 60 c 4886 c 4866 v c 4886 v c 4896 v 66 60 58 ? 68 c 4867 j 30 c 4887 c 4867 v c 4887 v c 4897 v 40 110 100 ? 130 c 4868 16 c 4887 j c 4867 vj c 4887 vj c 4897 vj 20 200 190 ? 200 c 4868 j 16 c 4888 c 4868 v c 4888 v c 4898 v 20 220 200 ? 250 4 kw 5 kw input vac, 1-phase input vac, 3-phase output amps output vdc 115 20% output amps 230 + 15% ? 20% 3x200 + 15% ? 20% 3x400 + 15% ? 20% 3x480 + 15% ? 20% adj. range b 4861 220 3) b 4881 b 4861 v b 4881 v b 4891 v 220 12 12 ? 16 b 4862 122 b 4882 b 4862 v b 4882 v b 4892 v 140 24 24 ? 32 b 4864 62 b 4884 b 4864 v b 4884 v b 4894 v 70 48 48 ? 64 b 4866 50 b 4886 b 4866 v b 4886 v b 4896 v 60 60 60 ? 80 b 4867 28 b 4887 b 4867 v b 4887 v b 4897 v 34 110 110 ? 145 b 4868 14 b 4888 b 4868 v b 4888 v b 4898 v 18 220 220 ? 290 battery chargers
euro cassetes powering progress ? www.powerbox.com.au doc. no. pbc9 rev.c 28-4-11 euro series euro option specifications options input option ?i? (inrush current limiting): a thermistor is connected in series with the input lines which changes its resistance from high to low when it gets hot. it does not reduce the current surge if the input power is interrupted for a short period of time not allowing the thermistor to cool down. thermistors are fitted as standard to all mains input models except for 1-phase input of models > 2.5kw. thermistors are available up to 45a. for higher input current an electronic inrush current limitation can be offered. option ?ie ? electronic inrush current limiting an electronic circuit limits the inrush current. option ?sd ? (series diode): a series diode protects the module against input voltage of wrong polarity (additional power losses). option ?ad ? (anti-parallel diode): to avoid the power losses of a series diode a diode is provided with opposite polarity in parallel to the input blowing an internal or external fuse if the module is connected to a supply with wrong polarity. option ?au ? (auto-ranging) for standard dual ac input models the range of 115/230vac is to be selected by connecting the input line to different pins on the connector. with auto-ranging the unit senses the input voltage and provides automatically the correct connection. option ?p ? (power fail): a signal (logic or relay) is given if the input voltage (ac or dc) drops below the specified limit. in ac input units we sense the rectified input voltage so that a power fail alarm will not be triggered if at light loads mains power returns before the input capacitors are substantially discharged. option ?r ? (relay): a relay instead of a logic signal is provided for failure indication. output option ?dd ? (decoupling diode): for redundant operation the outputs of two or more units are paralleled behind de-coupling diodes so that an internal fault of one module does not affect the operation of the others. these diodes cause power losses. option ?cs ? (active current sharing): an additional control circuit provides active current sharing via an interconnecting wire between converters that operate in parallel. active current sharing should be used for multi-output units operating in parallel. option ?csi ? (current sharing interrupt): option ?csi? will effect the removal of the ?cs? signal. should there be an instance where a unit is not supplying the load, then the effect of its ?cs? signal is removed, and the load voltage is unaffected by this condition. option ?h1 ? (inhibit): a te rminal connected to the negative input line also shuts off the converter. this can also be used in conjunction with a thermal trip which shuts the unit down. option ?h2 ? (inhibit): operation of the unit is inhibited if a voltage signal (5v/10ma) is applied in reference to the negative line of the (main) output. option ?rco ? (reducing current limiting at over temperature) a circuit reduces the current limiting level at higher temperature (to be specified). option ?d ? (dc-ok, one output): a logic signal is given if the output voltage (main output in multi-output systems) is below the specified limit. option ?m ? (dc-ok, all outputs): in multi-output systems a logic signal is provided if the voltage of any output is below the specified limit. option ?ac ? (ac ok) a logic signal connected to relay contacts is given if the output voltage of an inverter is below the specified limit. programming series 200-5800, 6600 of output voltage from 0 to 100% by external signal, 0-10vdc eu1 by external signal, 4-20ma eu2 by 270 potentiometer eu3 by 10 turn potentiometer eu4 of output current from 0 to 100% by external signal, 0-10vdc ei1 by external signal, 4-20ma ei2 by 270 potentiometer ei3 by 10 turn potentiometer ei4 isolating amplifier for programming iso programming via interface rs232 or ieee488 monitoring series 200-5800, 6600 of output voltage from 0 to 100% by external signal, 0-10vdc mu1 by external signal, 4-20ma mu2 of output current from 0 to 100% by external signal, 0-10vdc mi1 by external signal, 4-20ma mi2 isolating amplifier for programming iso programming via interface rs232 or ieee488 charger programming (all series) temperature compensated charging voltage(sensor not included) tc temperature sensor not interchangeable due to fixed resistor values ts1 interchangeable, ic controlled ts2 automatic selection of charging characteristic (float / equalize charge) with timer ch1 additionally: manual selection of charging characteristic ch2 additionally: boost charge operation (manually activated with time delayed return to normal operation) ch3 option ?y ? (sys-reset): this logic signal is a combination of power fail and dc-ok as specified for vme systems. option ?r ? (relay): a relay instead of a logic signal is provided for failure indication.` programming & monitoring
euro cassetes doc. no. pbc9 rev.c 28-4-11 environment option ?t ? (tropical protection):the unit is given additional protection by a heavy coat of varnish on the printed circuit board(s) and components. option ?c ? (extended temperature range):the circuit is designed and tested for operation at an ambient temperature as low as ?40 c. option ?ms ? (increased mechanical strength): screws are secured by locktite and heavy components are fastened by ties and/or glue. modules with the ?ms? option meet the standard en61373 regarding shock and vibration. mechanics standard mounting ? eurocassette ? pluggable module for 19? sub-racks 84te option ?w ? (wall mounting): module is screwed against a mounting plate for installation in a cabinet. the load connections are typically a terminal block. option ?cha ? (chassis mount) module is designed for installation to a structure or within cabinet. screw type connectors are supplied with the module. option ?din ? (din rail mount) module is designed for din rail mounting to a structure or within cabinet. screw type connectors are supplied with the module. programming / monitoring- series 6400 programming of output voltage and current from 0-100% including isolation by external signal, 0-10vdc e1 by external signal, 4-20ma e2 programming of output voltage from 0-100% by 270 potentiometer eu3 by 10 turn potentiometer eu4 programming of output current from 0-100% by 270 potentiometer ei3 by 10 turn potentiometer ei4 monitoring of output voltage and current from 0-100% including isolation by external signal, 0-10vdc m1 by external signal, 4-20ma m2 remote on/off programming and monitoring of output voltage and current from 0-100% including isolation by external signal, 0-10vdc em1 by external signal, 4-20ma em2 via rs232 and ieee488 em3 improved tolerance between reference (external signal) and measured value / between measured value and displayed signal: voltage 0.2% and current 0.5%. tol euro series euro option specifications


▲Up To Search▲   

 
Price & Availability of C4800

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X